Page 764 - Radiation Safety
P. 764

General Rules for Using Personal Monitoring Devices






                               9.     Dosimeters must not be worn during non-occupational exposure, such as

                                      during treatments with medical x-ray.

                               10. Dosimeter should be protected against damage by heat, moisture, pressure

                                      and contamination.


                               11. Dosimeters not in use should be stored in clean area (e.g. administration

                                      office).


                               12. Dosimeters shall be changed on a monthly basis or on a duration as permitted

                                      by the authority.


                               13. Use the old dosimeters until the new one is received. Change the old one

                                      with the new dosimeter at the beginning of the month. Return the used

                                      dosimeters to the service center for dose analysis.


                               Note:

                               ➢      Finger dosimeter should also be used if hands are likely to receive higher radiation exposure than

                                      other parts of body.
                               ➢      In cases of radiation accident or a higher dose is suspected, return the relevance dosimeter

                                      immediately to the service provider.