Decision Making For Found Source Or Contamination                                                                                                                                                                                                                                                                                                  27





















                                                                                                    Source or                                Dominant radiological                                Hazard
                                                        Condition                                                                                                                                                                                                          Main actions
                                                                                                package type                                               hazard                                   level





                                                                                                                                                                                                                          1. Recover the source.
                                                                                                                                                                                                                          2. Ensure source is in its shielding and not missing.
                                                  Shielded source                                    Unknown                                    External exposure                                    Low                  3. Check the integrity of the source and shielding.

                                                                                                                                                                                                                          4. Find owner of the source.




                                                                                                                                                                                                                          1. Do not handle the source until the Radiological Assessor is present.
                                                                                                                                                                                                                          2. Isolate the area to 30 m.
                                                                                                                                                                                                                          3. Call the Radiological Assessor.
                                                                                                                                                External exposure                                    Low
                                                                                                     Unknown                                                                                                              4. Identify and segregate potentially exposed or contaminated people.
                                                                                                                                             Surface contamination                                 to high                5. Survey and recover the source.

                                                                                                                                                                                                                          6. Find the owner of the source.

                                                                                                                                                                                                                          7. Survey area and clean up as required.




                                                                                             Consumer product                                           Negligible                                                        1. Recover the source.

                                                                                             Calibration source                                                                                      Low                  2. Find the owner of the source.
                                                       Unknown

                                                       conditions
                                                              or                                                                                                                                                         1. Do not handle the source until Radiological Assessor is present.
                                                 damaged source                                                                                                                                                          2. Isolate the area to 10 m.
                                                                                               Industrial gauge                                                                                                          3. Call the Radiological Assessor.

                                                                                                  Well logging                                  External exposure                                 Medium                 4. Identify and segregate potentially exposed or contaminated people.
                                                                                              Moisture detector                              Surface contamination                                 to high               5. Survey and recover the source.
                                                                                                                                                                                                                         6. Find the owner of the source.

                                                                                                                                                                                                                         7. Survey area and clean up as required.


                                                                                                                                                                                                                          1. Do not handle the source until the Radiological Assessor is present.

                                                                                                                                                                                                                          2. Isolate the area to 30 m.
                                                                                                                                                External exposure                                                         3. Call the Radiological Assessor.
                                                                                                Brachytherapy                                Surface contamination                                                        4. Identify and segregate potentially exposed or contaminated people.
                                                                                                  Radiography                                           Inhalation                                   High                 5. Notify medical authorities.

                                                                                                   Teletherapy                                          Ingestion                                                         6. Survey and recover the source.
                                                  Found source or                                                                                                                                                         7. Find the owner of the source.

                                                    contamination                                                                                                                                                         8. Survey area and clean up as required.